Background: During the operation of X-ray machines, radiology personnel and individuals in adjacent areas may inadvertently be exposed to harmful doses of ionizing radiation.
Objective: This study examines the levels of secondary radiation in two busy radiology departments of secondary health facilities in Kano metropolis.
Methods: Radiation doses were measured using a Radiation Alert Ranger MultiPurpose Digital Survey Meter at various locations by taken first the background radiation, including the control panel, changing room, patient waiting area, protected cubicle, dark room/digitizer, and radiographer’s office.
Results: The highest measurement was 22.653 μSv/h in the changing room at Hospital 'B', and the lowest was 0.011 μSv/h in the patient waiting area at Hospital 'A'. Background radiation levels ranged from 0.077 to 0.203 μSv/h, with the highest levels recorded in the CT unit at Hospital 'B'.
Conclusion: The study emphasizes the need for continuous monitoring and stringent control of radiation exposure to ensure the safety of medical staff and the general public.
Downloads
Article Details
Section

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
All articles in JRRS are published under the Creative Commons Attribution 4.0 International License (CC BY 4.0). This permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
How to Cite
References
1- Owusu-Banahene, J., Darko, E. O., Charles, D. F., Maruf, A., Hanan, I., &Amoako, G. (2018). Scatter Radiation Dose Assessment in the
Radiology Department of Cape Coast Teaching Hospital-Ghana. Open Journal of Radiology, 08(04), 299–306. https://doi.org/10.4236/ojrad.2018.84033
2- Holmberg, O., Malone, J., Rehani, M., McLean, D. and Czarwinski, R. (2010) Cur-rent Issues and Actions in Radiation Protection of Patients. European Journal of Radiology, 76, 15-19. https://doi.org/10.1016/j.ejrad.2010.06.033
3- Eshiet, P., Dlama, J., Tom, A., Musa, G., Kpaku, G., & Mundi, A. (2016). Assessment of Radiation Protection Measures in a Nigerian
Tertiary Health Care Center. 16.
4- Bari, D. S., Amin, P. M., &Abdulkareem, N. A. (2015). Measurement of the Effective Dose Radiation at Radiology Departments of Some
Hospitals in Duhok Governorate. Journal of Modern Physics, 06(05), 566–572. https://doi.org/10.4236/jmp.2015.65061
5- ICRP (2012) International Commission on Radiological Protection, ICRP Statement on Tissue Reactions. Early and Late Effects of Radiation in Normal Tissues and Or-gans. Threshold Doses for Tissue Reactions in a Radiation Protection Context. An-nals of the ICRP Publication 118, 41(1/2).
6- UNSCEAR (2008) United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and Effects of Ionizing Radiation,
Report to the General Assem-bly Scientific Annexes A: Medical Radiation Exposures. UNSCEAR Vol. I.
7- Chinangwa, G., Amoako, J. K., & Fletcher, J. J. (2017). Radiation dose assessment for occupationally exposed workers in Malawi. Malawi Medical Journal, 29(3), 254. https://doi.org/10.4314/mmj.v29i3.5
8- Kalyvas, N. (2013). Measurement of scatter radiation spectrum from radiographic units. European Congress of Radiology.
https://doi.org/10.1594/ecr2013/c-0309
9- Naji, A. T, &Jaafar, M. S. (2013). Reduction of backscattered radiation in an x-ray room by using fabricated iron steel grid. Advances in
material physics and chemistry, 0(3), 191-193. http://dx.doi.org/10.4236/ampc.2013.33027
10- Daniel, O., Ogbanje, D. and Jonah, S.A. (2013) X-Ray and Scattering from Filters Used in Diagnostic Radiology. International Journal of
Scientific and Research Publications, 3, Issue 7.
11- ICRP (2007) International Commission on Radiological Protection Recommendations of the ICRP. Annals of the ICRP Publication 103, 37 (2-4).