Purpose: To determine and establish doses in paediatric radiography for hospitals which have no previous data.


Materials and Methods: X-ray examination data were collected and used as input in a dose calculation software (DOSECAL, from St. Georges’ Hospital, London) to obtain absorbed doses to the skin (entrance surface dose, ESD) as well as organ and effective doses. The study covered five common radiological examinations.


Results: Entrance surface and effective doses were found to be generally higher in agreement with an earlier study using thermoluminescent dosimetry, while organ doses were lower than the values for similar age groups in the literature. Causes of these high doses are attributed to the type, age and conditions of radiographic equipment, radiographic exposure factors (low kVp - which also accounts for low organ doses, and high mAs in some cases), film processing conditions and lack of quality assurance programmes. Suggestions and recommendations are outlined for dose reduction to within recommended international limits.


Conclusion: Doses obtained in this study will serve as a basis for comparison of future studies in the area.

Downloads

Download data is not yet available.

Article Details

Section

Articles

How to Cite

Egbe, N. O., Inyang, S. O., Bernard, O., & Azogor, W. E. (2026). ESTIMATES OF PAEDIATRIC DOSES FOR COMMON RADIOGRAPHIC PROCEDURES IN SOME NIGERIAN HOSPITALS. Journal of Radiography and Radiation Sciences, 22(1), 66-79. https://doi.org/10.82547/jrrs.vol22no1.134

References

Huda, W., Gkanatsios, N. Effective dose and energy imparted in diagnostic radiology. Medical Physics, 1997; 24(8):1311–1316.

Huda, W. Assessment of the problem: Paediatric doses in screen-film radiography. Pediatric Radiology, 2004; 34(Suppl 3):S173–S182.

Mohammadain, K.E.M., da Rosa, L.A.R., Azevedo, A.C.P., Guebel, M.R.N., Boechat, M.C.B., Habani, F. Dose evaluation for paediatric chest x-ray examinations in Brazil and Sudan: Low doses and reliable examinations can be achieved in developing countries. Physics in Medicine and Biology, 2004; 49:1017–1031.

Axelsson, B., Khalil, C., Lidegram, M., Schuwert, P., Mortensson, W. Estimating the effective doses to children undergoing heart investigations: A phantom study. British Journal of Radiology, 1999; 72:378–383.

International Commission on Radiological Protection (ICRP). ICRP Publication 26: Recommendations of the International Commission on Radiological Protection. Annals of the ICRP, 1977; 1(3). Pergamon Press, Oxford.

European Commission. European Guidelines on Quality Criteria for Diagnostic Radiographic Images in Paediatrics (EUR 16261). 1996.

Nigerian Nuclear Regulatory Authority (NNRA). Radiation Safety Regulations 2006: Radiotherapy, Nuclear Medicine and Diagnostic Radiology. Lagos: Federal Government of Nigeria; 2006.

Ogundare, F.O., Ajibola, C.L., Balogun, F.A. Survey of radiological techniques and doses in children undergoing some common x-ray examinations in three Nigerian hospitals. Medical Physics, 2004; 31(3):521–524.

Almen, A., Mattsson, S. The radiation dose to children from x-ray examinations of the pelvis and urinary tract. British Journal of Radiology, 1995; 68:604–613.

Roebuck, D.J. Risk and benefit in paediatric radiology. Pediatric Radiology, 1999; 29:637–640.

United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Sources and Effects of Ionizing Radiation. Report to the General Assembly, with Scientific Annexes, Vol. 1. United Nations, 2000.

Azevedo, A.C.P., Osibote, O.A., Boechat, M.C.B. Paediatric x-ray examinations in Rio de Janeiro. Physics in Medicine and Biology, 2006; 51:3723–3732.

Hart, D., Hillier, M.C., Wall, B.F. Doses to Patients from Medical X-ray Examinations in the UK – 2000 Review. NRPB-W14. National Radiological Protection Board, Chilton, Didcot; 2002.

Hart, D., Wall, B.F., Shrimpton, P.C. Reference Doses and Patient Size in Paediatric Radiology. NRPB Report R318. National Radiological Protection Board, Oxon; 2000.

Geleijns, J., Broerse, J.J., van Vliet, M., Lopez, N., Zonderland, H.M. Assessment of effective dose in paediatric radiology: A survey at 14 Dutch hospitals. Radiation Protection Dosimetry, 2000; 90(1–2):135–140.

Compagnone, G., Pagan, L., Bergamini, C. Effective dose calculations in conventional diagnostic examinations for adult and paediatric patients in a large Italian hospital. Radiation Protection Dosimetry, 2005; 114(1–3):164–167.

Hart, D., Jones, D.G., Wall, B.F. Coefficients for Estimating Effective Doses for Paediatric X-ray Examinations. NRPB-R279; 1996.

Perlmutter, N., Arthur, R.J., Beluffi, G., Cook, V., Horwitz, E.A., Kramer, P., et al. The quality criteria for diagnostic radiology images in paediatrics. Radiation Protection Dosimetry, 1998; 80(1–3):45–48.

Egbe, N.O., Inyang, S.O., Ibeagwa, O.B., Chiaghanam, N.O. Paediatric radiography entrance doses for some routine procedures within eastern Nigeria. Journal of Medical Physics, 2008; 33(1):19–35.

Simpson, P.D., Martin, C.J., Darragh, C.L., Abel, R. A study of chest radiography with mobile x-ray units. British Journal of Radiology, 1998; 71:640–645.

Padovani, R. The importance of education and training in reducing patient doses. European Radiology Syllabus, 2004; 14:2–8.

Lee, S.C., Wang, J.N., Liu, S.C., Jiang, S.H. Effective dose evaluation for chest and abdomen x-ray tests. Radiation Protection Dosimetry, 2005; 116(1–4):613–619.

Similar Articles